The 1100-CLEAR series of water-based concrete curing compounds is formulated from hydrocarbon resins and may be used on interior, exterior, vertical, and horizontal concrete surfaces. Once applied, 1100-CLEAR forms a premium-grade membrane that retains an optimum amount of water in freshly placed concrete for complete hydration of the cement.
NOTE: After approximately four weeks, the membrane begins to chemically break down. The membrane will eventually dissipate from the surface. This process usually takes another 3 - 5 weeks under normal traffic, exposure to UV, and weathering conditions.
Preparation...Application equipment must be clean and free of all previously used materials.
Mixing...For optimum performance, gentle mixing or agitation is recommended. CAUTION: TO AVOID FOAMING, DO NOT MIX EXCESSIVELY. DO NOT THIN.
Application Method ...Apply in a uniform film to horizontal surfaces as soon as the surface water disappears and the surface will not be marred by walking workmen. On vertical surfaces, apply promptly after the forms are removed. 1100-CLEAR may be applied with a typical commercial hand or power sprayer. Use a Chapin 5797 or equivalent spray nozzle that produces a flow of 1/2 gal. (1.89 L) per minute under 40 psi (.276 MPa) of pressure.
Coverage...Approximately 200 ft.²/gal. (4.91 m²/L). Coverage rate may vary depending on conditions (temperature, wind, etc.) at the jobsite, as well as the porosity and condition of the concrete.